4Question

Simple trouble and treatment of automatic soldering machine


Simple fault and handling method

1, after the power is connected, the machine is not powered up:

Check whether the socket is loose, check whether the power switch is open, and check whether the fuse is blown.

2. Manual delivery of tin does not come out of tin:

Check whether the adjusting bolt of the tin feeder is in place.

3, the position of machine is deviate from its operation.

Check whether the fixture position changes, let the machine reset once again to check whether there is any deviation.

4, the handheld display device does not display, displays half or displays the garbled Code:

When the standby interface is refreshed according to F2, check whether the connection line is loose, and re-energize it once. Before connecting the tutor, it should be determined that the power is off before connecting.

Matters needing attention in automatic soldering machine

1. Keep the machine clean and grease can be properly coated.

2. The XY axis should be moved manually to the middle of the machine before the machine is powered on, so as not to rush out of the origin limit when it comes back to the origin.

2. In the standby state, the machine must be reset before running the processing documents, so as to avoid collision.

3, do not touch the moving parts with your hands when running the machine.

4. When the machine is not at the origin, the start switch and the correction switch are prohibited.

5, when changing the soldering iron, the iron part should be cooled sufficiently to avoid scalding.

6, avoid foreign bodies falling into the machine so as not to damage the machine.

7, check regularly whether the screws of the moving parts are loose, and tighten them in time.