4Information

Common problems and analysis of winding machine


When using the winding machine, customers may encounter the following situations:

First, after the start button is pressed, the motor does not turn.

Second, count but do not line up, and after the boot, the reset action is normal.

Third, the number of cycles is set.

Fourth, do not reset after winding.

Fifth, do not start automatically.

Sixth, it's a waste of time after finishing the reset.

In view of the above problems, give you the following analysis:

The first case is that the motor speed is too low to overcome the resistance after the line. At this point, you can try to reduce the percentage of high and low speed. It may also be due to inverter protection, low voltage and high voltage protection, overcurrent protection so that the motor is not working. If so, you can try to turn off the power supply, check the power supply voltage and external load, confirm that there is no problem before turning on the power supply.

The second scenario: it may be because you set the line diameter or width to be zero or because you set the starting point + width & gt when you line from inside to outside; the width & gt when you arrange the line stroke or from outside to inside; and the starting point, you can set the correct line diameter or width. It may also be due to the wrong setting of the wiring mode, which requires you to set the correct way of wiring.

Third case: it may be because the speed is too fast, so you have to reduce the percentage of low speed. It may also be because the number of pre stop rings is too small, you can increase the number of pre stop cycles.

The fourth scenario: Maybe you set the automatic reset item to zero, and then you need to set the automatic reset item to 1.

Chapter 5: Maybe because the automatic starter is set to zero, you can set the automatic starter to 1, and then debug it.

Sixth case: Maybe you set the number of resets in the user parameters to 1, in which case you can set the number of resets to a larger value.

For these common problems, the majority of users should be carefully considered, hoping that the above content will help you.